BENEFITS

  • UP TO 87% ANNUALLY MORE ENERGY PRODUCTION in comparison with standing PV systems;
  • MORE CO2 EMISSIONS SAVED in ton equivalent;
  • MORE EFFICIENCY per unit area;
  • ECO FRIENDLY with less direct environmental impact;
  • LESS AREA INTERACTION;
  • ONLY 9 700sq.m surface for 1 MW installed capacity;
  • Perfect for LARGE SCALE PROJECTS;
  • A DYNAMIC HIGHLY VERSATILE STRUCTURE which meets the fast-developing market
  • ANY type and size of MODULES can be accommodated within the structure (from 400Wp to 6-7-800Wp and more);
  • Effective multi technical design for:
  • ROOF with any incline;
  • GROUND construction no matter the substrate or incline;
  • Small, medium and large ENTERPRISE
  • MULTI USE AREAS for example PARKING or remain       I    aavailable for other purposes;
  • ENVIRONMENTALLY friendly, economically efficient and a SMALL AREA SURFACE TO INTERACTION
  • MULTIPLE TYPES AND HEIGHTS of BASE From single pylon to tower structure with height from 0,4 up to 10-meter height;
  • EASILY ASSEMBLED, TRANSPORT AND DELIVERY;
  • INTERCHANGABLE with existing PV amortized projects;
  • HEXAGON SHAPE which allows maximum effective utilization on ANY PLOT SHAPE or SIZE;
  • The INTERNAL MODULES PLACEMENT with wind corridors which:
  • Allow the CONSTRUCTION TO COOL;
  • Make it MORE RESISTANT TO VARIABLE WEATHER conditions;
  • Allow less DUST FORMATION;

ELECTRIC PART

Monitoring system Network Control Unit / SCADA interface
Tracking control system TdAPS (Time derived astronomical positioning system)
Control system

 

Protection against turning more than 300 degrees;

Self-powered wireless controller;

RS485, Ethernet, WLAN

Type of application program for supervision and settingsiSolar Cloud – available for Windows, Android and iOS
Monitoring, setting and changing data onlineYes
Turned on the position onlineYes
Turning time intervalEvery 15min.
Type for communication interfaceWireless, Ethernet, USB interface
Updating possibility onlineYes

Download iSolar Cloud

COMPLIANCE AND OPERATION

Compliance

 

IEC 61215/ IEC 61730 / IEC 61701 / IEC 62716 ISO 9001: Quality Management Systems;

IEC 62109, IEC 61727, IEC 62116, IEC 60068, IEC

61683, VDE-AR-N 4110:2018,

VDE-AR-N 4120:2018, IEC 61000-6-3, EN 50438,

AS/NZS 4777.2:2015, CEI 0-21,

VDE 0126-1-1/A1 VFR 2014, UTE C15-712-1:2013, DEWA

Protection classIP66/IP68/IP54
Materialgalvanized steel/stainless steel S235JR по БДС EN 10219-1:1997, БДС EN 10219-1:2006/NA:2011

S235JR БДС EN 10025-2, БДС EN 1993-1-1:2005/NA:2011

Corrosion classstandard C3, optional C4 or more
Operating temperature range-40 °C to +60 °C / -45.4 °F to 140 °F
FoundationConcrete (customizable all steel foundation)

Piles, Column;

Max. wind speedMax. wind speed in storm up to 167 km/h up to 105 mph (3-sec. gust) position (standard)
Wind protectionIntelligent wind absorption by reduction system for maximum array stability in all wind conditions.
Snow load108kg/sq.m
Warranty10 years on structural components;

5 years on drive and control

systems.

Extended terms available upon a request.

TRACKING RANGE

Azimuth angle rangeFrom sunrise to sundown – 260° (± 1°) –
Tilt angleSeasonable by solstice – adjustable to exact latitude.
Tracker accuracy Up to 0.1°
Type of tilt angle driveDrive motor Un=230V, P=0,37kW, In=2,63A, n=1348min-1

 

Type of tilt angle driveManually calibration 2 to 4 times during the year
Power / modules per tracker

 

4,4kWp – 8 modules;

5,5kWp- 10 modules;

6,6kWp- 12 modules;

8,8kWp- 16 modules;

15,95kWp -29 modules;

18,7kWp- 34 modules;

 

*550Wp module single capacity

ShapeHexagon
TrajectoryCircle
Rotation Trajectory

 

D=7.15m – 8 pcs. tracker

D= 8.20m – 10pcs. tracker

D= 8.80m – 12pcs. tracker

D= 10.35m – 16pcs. tracker

D= 14.30m – 29pcs. tracker

D= 14.60m – 34pcs. tracker

Sq.m per trackerS=40.04sq.m – 8 pcs. tracker

S=52.82sq.m – 10pcs. tracker

S=60.82sq.m – 12pcs. tracker

S=84.13sq.m – 16pcs. tracker

S=160.61sq.m – 29pcs. tracker

S=167.42sq.m – 34pcs. tracker

Area interaction per 1MWp (54 trackers with 34pcs.) installed capacity 9 538,02 sq.m – with servicing areas and distance from column to column -15m.

9040,68 sq.m without servicing area

Height per tracker on land/roofMin. 0.4m from the ground/roof up to 1.5m
Heigh per tracker in urban areas/parkingFrom 2m. from the ground up to 4m.

*Higher constructions area available upon a request

Max weight with solar modules 2250kg
Estimated tracker live25 years
Electromagnetic compatibility Yes
Ground cover ratio > 84%
Stow position Yes
Night positionYes
Backtracking Yes
Maintenance position Yes

Pv systems are perfect for:

Due to the many implemented technological solutions, the system occupies only 9700 sq.m. for 1MWp installed capacity, which makes it the first two-axle tracker system suitable for large-scale projects.

FOR ANY TYPE OF PLOT/ROOF AND SHAPE

The hexagon shape of the structure and its different sizes (number of modules) allow each plot/roof, regardless of its shape, to be maximized in order to increase the productivity per unit area.

URBAN AREAS

PV SUN can be placed on a pylon/column structure up to 10m. high and because there is only single base located centrally with an area of ​​1 sq.m, which makes it extremely suitable for urban areas.

PARKING/CHARGING STATIONS

Because PV SUN can be placed on a pylon structure up to 10 m high with a single base – located centrally, it can be used for a dual purpose: power plant-parking, which can power charging stations for electric vehicles. In this way, the energy used to charge environmentally friendly cars will be truly “green”.

ROOFS

The PV SUN system is suitable for installation on roofs, whether they have a reinforced concrete structure or a reinforced lattice.

MANUFACTURING ENTERPRISES

The system is perfect for factories for several reasons: all free and suitable terrains can be used – roofs, parking lots, free surrounding area and thus free electricity can be provided only after the 2nd year of commissioning of the installation for 23-28 years;

–  saved taxes from fees for transmission, access, debt to society; saved grid electricity losses, as the produced energy will be consumed at the place of production.

REPLACEABLE WITH OLD INSTALLATIONS

PV SUN is ideal for replacing old power plants, as they can be used to double productivity with less space and use existing permits for construction and connection to the electricity grid.

GROUND STRUCTURES

PV SUN is suitable for any type of terrain, regardless of its geodesy, as it can be placed with anchors on rocky terrain, with a column-compacted structure in sandy soils or concrete foundations dug into the ground …

We can offer you the following types of constructions size and capacity:

PV SUN EVE MODELS MODULS Modul /sq.m./ Modul Capacity /Wp/ Tota lsq.m. Total Capacity /kWp/
PV SUN EVE 34 34 14.6 550 167.23 18.7
PV SUN EVE 29 29 14,3 550 160.61 15,95
PV SUN EVE 16 16 10,35 550 84.13 8,8
PV SUN EVE 12 12 8.8 550 60.82 6.6
PV SUN EVE 10 10 8.2 550 52.82 0.55
PV SUN EVE 08 8 7.15 550 40.04 4.4